Sign In | Join Free | My himfr.com
Home > Portable Water Chiller >

30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes

    Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
     
    Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
    • Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
    • Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
    • Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
    • Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers
    • Buy cheap 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes from wholesalers

    30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes

    Ask Lasest Price
    Brand Name : Anges/SZAGS
    Model Number : ACK-30(D)
    Certification : CE/ISO9001
    Price : Negotiatible
    Payment Terms : 50%TT advance, 50%TT balance
    Supply Ability : 800 sets/ month
    Delivery Time : 10~35days
    • Product Details
    • Company Profile

    30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes

    30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes

    The benefits of using chiller:


    ①Efficient Cooling: Chillers provide consistent and efficient cooling, ensuring stable operating temperatures for various industrial processes and equipment.


    ②Energy Savings: Modern chillers are designed with energy-efficient features, helping to reduce energy consumption and lower operating costs.


    ③Process Control: Chillers offer precise temperature control, allowing users to maintain optimal conditions for their specific applications, which can improve product quality and consistency.


    ④Equipment Protection: By controlling temperatures, chillers help to prevent overheating and damage to sensitive equipment, extending its lifespan and reducing maintenance requirements.


    ⑤Environmental Impact: Chillers with environmentally friendly refrigerants contribute to sustainability efforts by reducing greenhouse gas emissions and minimizing ozone depletion.


    How to select the model of the chiller?


    1.Determine Cooling Load:
    Calculate the cooling load required for your application. This is usually measured in tons of refrigeration (TR) or kilowatts (kW).
    Consider factors like the size of the space, heat generated by equipment, and external environmental conditions.


    2.Type of Chiller:
    Air-cooled chillers: Typically used for smaller applications and are easier to install and maintain.
    Water-cooled chillers: More efficient for larger applications but require cooling towers, more maintenance, and more space.


    3.Application and Environment:
    Assess whether the chiller will be used for industrial processes, comfort cooling, or other specific applications.
    Consider the ambient temperature and environmental conditions where the chiller will be installed.


    4.Energy Efficiency:
    Look for chillers with high Coefficient of Performance (COP) or Energy Efficiency Ratio (EER).
    Consider chillers with variable speed drives (VSD) for better energy management and efficiency.


    5.Capacity Control:
    Evaluate if the chiller can modulate its capacity to match the varying cooling load. This helps in saving energy and improving efficiency.


    6.Size and Footprint:
    Ensure the physical size and footprint of the chiller fit within the space available for installation.


    7.Initial and Operating Costs:
    Balance between the initial purchase cost and the operating costs (energy consumption, maintenance).
    Consider the total cost of ownership over the chiller’s lifespan.


    8.Reliability and Maintenance:
    Check the reliability and ease of maintenance of the chiller.
    Look for models with good service support and availability of spare parts.


    9.Regulatory Compliance:
    Ensure the cooler complies with local regulations and standards, including environmental regulations.


    10.Manufacturer and Warranty:
    Choose reputable manufacturers with good after-sales service and support.


    By considering these factors and following these steps, you can select a chiller model that is efficient, reliable, and suitable for your specific application.


    Specification

    Technical Parameter of Industrial Air-cooled Chiller

    Model

    Item

    ACK-30(D)
    nominal cooling capacitykcal/h95357
    kw110.88
    input powerkw29.92
    power supply3PH 440V 60Hz
    refrigeranttypeR407C
    type of controlthermostatic expansion valve
    compressortypehermetic scroll
    power(kw)24.92
    condensertypefinned copper tube + low noise outer rotor fan
    cooling air flow(m3/h)40000
    evaporatortypeshell and tube
    chilled fluid flow (m3/h)19.12
    volume (L)240
    inlet and outlet pipe diameter (inch)2-1/2
    pumppower(kw)2.2
    lift(m)20
    safety protectioncompressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection
    weightkg1300
    dimensionmm2300*1480*1900

    Note: 1. Nominal cooling capacity is according to:

    Inlet chilled fluid temperature: 17℃

    Outlet chilled fluid temperature: 12℃

    Inlet cooling air temperature: 30℃

    Outlet cooling air temperature: 35℃

    2. Working range:

    The temperature range of chilled fluid is from 5℃ to 35℃;

    Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

    It is better to use the chiller while the ambient temperature at or below 40℃.

    We reserve the right to modify the above dimensions or parameters without further notice.


      FAQ

      1.How does a chiller system work?

      The chiller operates with two circulations: one involves the circulation of process water, while the other entails the circulation of refrigerant gas. Heat absorbed from the process is transferred to the refrigerant circulation, and then expelled to either air or water.


      2.How to select the model of the chiller?

      1.Determine Cooling Load:

      Calculate the cooling load required for your application. This is usually measured in tons of refrigeration (TR) or kilowatts (kW).

      Consider factors like the size of the space, heat generated by equipment, and external environmental conditions.


      2.Type of Chiller:

      Air-cooled chillers: Typically used for smaller applications and are easier to install and maintain.

      Water-cooled chillers: More efficient for larger applications but require cooling towers, more maintenance, and more space.


      3.Application and Environment:

      Assess whether the chiller will be used for industrial processes, comfort cooling, or other specific applications.

      Consider the ambient temperature and environmental conditions where the chiller will be installed.


      4.Energy Efficiency:

      Look for chillers with high Coefficient of Performance (COP) or Energy Efficiency Ratio (EER).

      Consider chillers with variable speed drives (VSD) for better energy management and efficiency.


      5.Capacity Control:

      Evaluate if the chiller can modulate its capacity to match the varying cooling load. This helps in saving energy and improving efficiency.


      6.Size and Footprint:

      Ensure the physical size and footprint of the chiller fit within the space available for installation.


      7.Initial and Operating Costs:

      Balance between the initial purchase cost and the operating costs (energy consumption, maintenance).

      Consider the total cost of ownership over the chiller’s lifespan.


      8.Reliability and Maintenance:

      Check the reliability and ease of maintenance of the chiller.

      Look for models with good service support and availability of spare parts.


      9.Regulatory Compliance:

      Ensure the cooler complies with local regulations and standards, including environmental regulations.


      10.Manufacturer and Warranty:

      Choose reputable manufacturers with good after-sales service and support.


      By considering these factors and following these steps, you can select a chiller model that is efficient, reliable, and suitable for your specific application.


      4. What kind of after-sales service can we provide?

      24 hours Online support;


      Video technical support;


      Overseas third-party support available and etc.


      Quality 30HP Industrial Air Cooled Scroll Type Water Chiller Portable Cooling System for Injection Processes for sale
      Inquiry Cart 0
      Send your message to this supplier
       
      *From:
      *To: Shenzhen Anges Machinery Co., Ltd
      *Subject:
      *Message:
      Characters Remaining: (0/3000)