Sign In | Join Free | My himfr.com
Home > Portable Water Chiller >

25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM

    Buy cheap 25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM from wholesalers
     
    Buy cheap 25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM from wholesalers
    • Buy cheap 25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM from wholesalers
    • Buy cheap 25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM from wholesalers

    25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM

    Ask Lasest Price
    Brand Name : Anges/SZAGS
    Model Number : ACK-25(D)
    Certification : CE/ISO9001
    Price : Negotiatible
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 800 sets/ month
    Delivery Time : 10~35days
    • Product Details
    • Company Profile

    25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM

    25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System for IMM


    Industrial chillers are versatile pieces of equipment used in a wide range of industries to cool processes, machinery, and products. Here are some key industries where industrial chillers are commonly utilized:

    1.Manufacturing:
    ①Plastic Industry: For cooling injection molding machines, blow molding machines, and extrusion processes.
    ②Metalworking: For cooling machining processes, welding equipment, and electroplating baths.
    ③Chemical Industry: For cooling reactors, mixers, and chemical processing equipment.

    2.Food and Beverage:
    ①Dairy Processing: For cooling milk, cream, and other dairy products.
    Breweries: For cooling wort during brewing and maintaining fermentation temperatures.
    ②Beverage Production: For cooling liquids during bottling and canning processes.

    3.Pharmaceutical:
    For cooling equipment in the production of drugs and maintaining precise temperature control in laboratories and production areas.

    4.Medical and Healthcare:
    MRI and CT Scanners: For cooling imaging equipment.
    Laboratory Equipment: For maintaining stable temperatures in various laboratory applications.

    5.HVAC (Heating, Ventilation, and Air Conditioning):
    ①For cooling large buildings, data centers, and industrial facilities.
    Energy and Power Generation:
    ②For cooling turbines, generators, and other power generation equipment.
    6.Printing Industry:
    For cooling printing presses and other printing equipment to ensure consistent quality and prevent overheating.

    7.Automotive:
    For cooling during the manufacturing of parts and assemblies, including paint booths and welding processes.

    8.Textile Industry:
    For cooling machinery used in the production and processing of textiles.

    9.Electronics:
    For cooling semiconductor manufacturing processes and electronic component testing.

    Each of these industries benefits from the precise temperature control, efficiency, and reliability that industrial chillers provide.


    Specification

    Technical Parameters of Industrial Air-cooled Chiller

    Model

    Item

    ACK-25(D)
    nominal cooling capacitykcal/h75542
    kw87.84
    input powerkw22.64
    power supply3PH 440V 60Hz
    refrigeranttypeR407C
    type of controlthermostatic expansion valve
    compressortypehermetic scroll
    power(kw)18.6
    condensertypefinned copper tube + low noise outer rotor fan
    cooling air flow(m3/h)30000
    evaporatortypeshell and tube
    chilled fluid flow(m3/h)15.14
    volume(L)220
    inlet and outlet pipe diameter(inch)2-1/2
    pumppower(kw)2.2
    lift(m)20
    safety protectioncompressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection
    weightkg1300
    dimensionmm2200*1130*2020

    Note: 1. Nominal cooling capacity is according to:

    Inlet chilled fluid temperature: 17℃

    Outlet chilled fluid temperature: 12℃

    Inlet cooling air temperature: 30℃

    Outlet cooling air temperature: 35℃

    2. Working range:

    The temperature range of chilled fluid is from 5℃ to 35℃;

    Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

    It is better to use the chiller while the ambient temperature at or below 40℃.

    We reserve the right to modify the above dimensions or parameters without further notice.


    FAQ

    1.How does a chiller system work?

    The chiller operates with two circulations: one involves the circulation of process water, while the other entails the circulation of refrigerant gas. Heat absorbed from the process is transferred to the refrigerant circulation, and then expelled to either air or water.

    2.How to select the model of the chiller?

    ①Determine Cooling Load:

    Calculate the cooling load required for your application. This is usually measured in tons of refrigeration (TR) or kilowatts (kW).

    Consider factors like the size of the space, heat generated by equipment, and external environmental conditions.

    ②Type of Chiller:

    Air-cooled chillers: Typically used for smaller applications and are easier to install and maintain.

    Water-cooled chillers: More efficient for larger applications but require cooling towers, more maintenance, and more space.

    ③Application and Environment:

    Assess whether the chiller will be used for industrial processes, comfort cooling, or other specific applications.

    Consider the ambient temperature and environmental conditions where the chiller will be installed.

    ④Energy Efficiency:

    Look for chillers with high Coefficient of Performance (COP) or Energy Efficiency Ratio (EER).

    Consider chillers with variable speed drives (VSD) for better energy management and efficiency.

    ⑤Capacity Control:

    Evaluate if the chiller can modulate its capacity to match the varying cooling load. This helps in saving energy and improving efficiency.

    ⑥Size and Footprint:

    Ensure the physical size and footprint of the chiller fit within the space available for installation.

    ⑦Initial and Operating Costs:

    Balance between the initial purchase cost and the operating costs (energy consumption, maintenance).

    Consider the total cost of ownership over the chiller’s lifespan.

    ⑧Reliability and Maintenance:

    Check the reliability and ease of maintenance of the chiller.

    Look for models with good service support and availability of spare parts.

    ⑨Regulatory Compliance:

    Ensure the cooler complies with local regulations and standards, including environmental regulations.

    ⑩Manufacturer and Warranty:

    Choose reputable manufacturers with good after-sales service and support.


    By considering these factors and following these steps, you can select a chiller model that is efficient, reliable, and suitable for your specific application.


    4. What kind of after-sales service can we provide?

    ①24 hours Online support;

    ②Video technical support;

    ③Overseas third-party support available and etc.


    Quality 25HP Portable Industrial Air Cooled Scroll Water Chiller Cooler System For IMM for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Anges Machinery Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)