    Brand Name : ANGES
    Model Number : 50HP
    Payment Terms : T/T, L/C
    Delivery Time : 25 days
    • Product Details
    • Company Profile

    50 Ton Water Cooled Screw Chiller 50HP Plastic Glycol Chiller

    Water Cooled 50HP Screw Chiller Plastic Process Chiller 50ton Screw Chiller Process Cooling Equipment Glycol chiller


    Which industrial applications need water chiller?
    Industrial water chillers are widely used in many industries like plastic and rubber manufacturing, electronic productions, electroplating, medical chemistry, ultrasonic cooling and printing business, etc.In the plastic manufacturing process, the chillers are used to cold the molds. It can accurately controls the temperature and cooling time by providing stable temperature, flow and pressure water to the molds. An adequate cooling system is required in some of the process of the plastic industry, ensuring the highest quality final products.

    The industrial water chiller temperature is from -45 to +30 ℃, compared with the water tower, the chiller can meet the various temperature requirements of industrial production. Choosing the right kind of industrial chiller for process cooling can lower cooling costs, minimize downtime, and improve operational efficiency.


    Should I Choose a Water cooled chiller or Air-cooled chiller for my plastic process?

    Water-cooled screw chillers are generally more efficient than air-cooled chillers, but higher cost in installation and maintenance due to the additional cooling water tower, tanks, and cooling pump.

    The water screw chiller is used for large capacity, it can be a plastic central chiller to cool several processes, in this way ,you can ruduce the chillers in the factory by using a central chiller, easiler for operation and maintenance.

    Plastic Central Chiller Specification

    Model

    Item

    AGS-050WSH
    nominal cooling capacitykcal/h161422
    kw187.7
    input powerkw39
    max running currentA88.9
    power supply3PH-380V-50HZ
    refrigeranttypeR22
    type of controlexpansion valve
    compressortypesemi-hermetic screw
    quantity1
    start-up modeY-△
    capacity control0-33-66-100
    evaporatortypeshell and tube
    chilled fluid flow (m3/h)32.3
    pipe diameter (inch)3
    condensertypeshell and tube
    cooling water flow (m3/h)39
    pipe diameter (inch)3”
    safety protectioncompressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection.
    dimensionmm2130*855*1540
    net weightkg950
    running weightkg1060

    Benefit of industrial chiller applications

    • Water-coold screw chillers could accurately provide the needed temperature for industrial manufacturing and largely improve efficiency.
    • Accurate temperature control capability, the freezing temperature can be accurate to ±1℃, ensure the highest quality final products.
    • Chillers can decrease equipment depreciation and degradation to cut down on operating expenditures.
    • TheScrew compressors can achieve comparable part-load efficiencies, whether you run your chiller more often at part or full load, it will save energy.

    Features of water-cooled water screw chillers

    1. Adjustable water temperature: Water cooled type chiller outptu chilled water from +5 to +30℃.Water temperature and flow rate can be designated and adjustable in control range.
    2. Stable performance: Screw compressor chiller is smple structure, less moving parts, low failure rate, high safety factor, large cooling capacity.
    3. Power saving and energy saving: Screw chiller capacity control can be four (100%-75%-50%-25%) or three (100%-66%-33%) automatic adjustment ability, which can effectively save energy consumption according to the actual use of heat load, so as to effectively save energy.
    4. Long service life: Shell and tube evaporator and condenser, the welded structure is simple, sturdy structure, high quality, compact structure, long life and so on.
    5. Simple installation and operation: This 60hp extruder chiller can be a central chiller to cool several processes, easy installation and operation with lower cost. It can work after connecting the production lines with water pipes. Small size, easy to install, and simple to operate.

    Water chiller service from manufacturer

    1. All the chillers are provided with 12 months free maintenance service.
    2. Provide technical explanation, chiller debugging support, technical training and chiller maintenance guidance.
    3. If necessary, after-sales engineers can be on-site service confirmed by both parties through communication .In some areas, local dealers can provide fast and convenient service.
    4. Provide the air chiller and water chiller required parts quickly to ensure the normal use of customers.If necessary, part of the wearing parts can be provided for backup after confirmation by both parties.
    5. Chiller maintenance service outside the warranty period, life-long tracking maintenance, cost price to provide equipment parts.

    Industrial water cooled Chiller installation

    This water cooled screw chiller system including the items below:


    Chiller
    Cooling tower
    Condenser cooling pump
    process chilled water pump

    1. Install the chiller unit in a steady, ventilated and easy-installation place, avoid corrosion, pollution and weather-beaten.
    2. Choose a suitable cooling tower to match the chiller unit.
    3. Pipeline should be installed according to the dimension of the chiller. Do not reduction the size of the hose, or it will affect the refrigeration effect and increase the power consumption.
    4. The chiller unit must be installed more than 1 meter away from the wall, so that it is easy to install, maintain and adjust

    Quality 50 Ton Water Cooled Screw Chiller 50HP Plastic Glycol Chiller for sale